Cloud hosting for plant data and applications
We run the hosted side of the system, the application, the history of every signal and the pipelines between them, with backups, retention you choose, and exports you can take whenever you want them.
For: IT and OT leads, plant managers and whoever owns the system's budget

Plant data systems often start on a PC under a desk in the maintenance office. It works until the disk fills, the one person who knew the database password leaves, or someone asks for last year’s numbers and finds there was never a backup. Cloud hosting is the part of OpenGXT’s work that keeps the system running somewhere safer, with the history kept as long as you decide and the data always yours to take.
The gateway on your network reads the equipment (see machine connectivity) and sends data outbound. Everything after that point is ours to run.
What we host and run
- The application. Shift boards, reports, check sheets, maintenance screens and energy dashboards, reached through a web browser by the people on your access list.
- The signal history. A time-series store of every signal with its timestamp and quality flag, plus the calculated values built from it, such as run minutes, OEE and energy per unit.
- The pipelines. The steps that take data from the gateway into storage, calculate each figure by the formula in your data dictionary, and send the shift report.
- Separate environments. A test environment where changes are tried before they reach the boards your operators use.
- Monitoring. Checks that each gateway is connected, each signal is arriving and each report has run, covered under support and maintenance.
- Backups. Scheduled backups stored separately from the live system, with restores tested, not just assumed.
- Exports. CSV and Parquet files, a SQL dump and a documented REST API, at every service level.
The questions IT and finance ask
Where is our data stored?
In the hosted environment named in your hosting description, which you receive before go-live. The gateway on site holds only a buffer of recent values while the connection is down. If your company has rules about where data may be kept, put them in the pilot plan and we will tell you in writing whether we can meet them.
Who can see it?
The named users on the access list you approve, each with a role that sets what they can see and change. OpenGXT staff access the system to support it, and that access is logged. We do not sell client data or pool it with other clients’ data. The security page explains how credentials, encryption in transit and access logging are handled, and how our approach is informed by NIST SP 800-82 and the NIST Cybersecurity Framework 2.0.
How long is it kept?
As long as you decide. Retention is set per type of data and written into a retention and backup schedule. Raw signals, calculated shift figures and quality records often have different needs, and quality records may have to be kept for as long as your customers require.
What does it cost to keep five years?
The storage depends on how many signals you collect, how often, how many values actually change, how well they compress and how long you keep them. The data volume estimator does that arithmetic. Hosting is priced in a written proposal after the survey, with the volume estimate attached so you can see what it is based on.
What if the internet is down?
The gateway keeps reading the machines and buffers the data, then sends it when the connection returns, so the shift record fills in rather than showing a gap. The connection plan states how the gateway is set up to buffer on your site.
Availability figures
We do not publish an uptime percentage. Before you compare any provider’s availability figure, find out what it allows: the uptime calculator turns a percentage into minutes per day, week, month and year. Then ask whether planned maintenance counts as downtime, and how and from where outages are measured. Those answers matter more than the number.
Example (fictional). A fictional beverage bottler’s Line 2 sends ten signals: the filler’s machine state, good count, reject count, active fault code, line speed, capper torque, two temperatures, the electricity meter and compressed-air flow. At one sample a second, with 20% of values kept after report-by-exception filtering, 16 bytes per stored value and 4 to 1 compression, that is 172,800 values a day and about 252 MB a year, or about 1.3 GB for five years of retention. If the bottler later connects 400 signals across the plant with the same settings, the estimate becomes 10.1 GB a year and 50.5 GB for five years. The retention schedule records the choice, and the export procedure shows how to take all of it out as Parquet files.
What you provide and what you receive
| You provide | You receive |
|---|---|
| Your retention requirements by type of data | A hosting description |
| A user list with roles | A retention and backup schedule |
| Your IT security requirements | An access list you approve |
| An outbound internet path for the gateway | A written export procedure |
| A person who approves access changes | A data volume estimate for your signals |
Leaving is planned at the start
At go-live you receive a written exit plan: what you get if you leave, including a full data export, schemas, configurations and documentation. The retrieval window after termination is written into each agreement. The rest of our commitments are on the open data page. To see how hosting fits with a first line, read about engagement types or plan a pilot line.
Start with one line.
Tell us which line you want to understand and the question you ask after every shift. We reply with questions or a time to walk it with you.