OpenGXT homePlan a pilot line
Menu

Energy monitoring for electricity, air, gas and water

Energy measured where it is used and divided by what the line actually made, so the monthly utility bill becomes energy per unit by line and shift, with idle use and peak demand in plain view.

For: Plant managers, facilities and energy leads, and maintenance managers

A miniature gray electrical panel feeds a thick cable to a row of three green machines while a tiny electrician holds a small clamp meter around one cable.

The utility bill tells you what the whole plant used last month and what it cost. It does not tell you which line used it, which shift, how much went into product and how much was spent while nothing was being made. Energy monitoring answers those questions by reading meters on the lines and the utilities, and dividing energy by the counts that production monitoring already records.

What we measure

  • Electricity. Submeters on the main feeders, on each line and on the largest machines, reading power and energy. Many existing power meters can be read over Modbus TCP or RTU through machine connectivity. New meters and current transformers are installed by your electricians or a licensed contractor.
  • Compressed air. Flow and pressure at the compressor room and on main headers, plus each compressor’s run and load state where its controller exposes it.
  • Gas and water. Meters with a pulse output or a communication interface, read by the same gateway.
  • Production. Good counts and machine states from the line, so energy can be divided by output and split by state.

Energy per unit, idle use and peak demand

Energy per unit is the energy used in a period divided by the good units made in it, by line and by shift. It turns a plant-wide bill into a number a line supervisor can compare from one week to the next. Compare periods with a similar product mix and weather, or normalize for them.

Idle consumption is the energy a line uses while it is idle, down or on a planned stop. Because each meter reading carries the machine state at the time, the software can show how much energy was spent while the line was making nothing.

Peak demand is the highest average demand in the interval your utility bills on. The software shows when each month’s peak occurred and which loads were running at the time, so you can see whether it was a start-up, a changeover or two large machines running together.

Compressed air and leaks

The U.S. Department of Energy’s compressed air tip sheet on leaks, published in 2004, calls leaks “a significant source of wasted energy” and says they often waste 20% to 30% of a compressor’s output. It suggests 5% to 10% of total system flow as a reasonable target for cost-effective leak reduction, and says “the best way to detect leaks is to use an ultrasonic acoustic detector.”

Software does not find leaks. Your team or a contractor does, with a detector. What the software adds is the measurement around the leak program: a baseline taken with no production demand on the system, a leak log with each tag’s location, estimated size and repair date, and the same baseline measured again after repairs. The tip sheet prices leaks as the number of leaks × leakage rate (cfm) × kW per cfm × hours × $/kWh. Our compressed air leak calculator estimates total leak flow from compressor load and unload times with no production demand, then applies the same chain of flow, power, hours and price.

The questions buyers ask

Which meters do we need?

Fewer than most people expect at the start. We write a metering plan from your utility bills and your single-line diagram or panel schedule, beginning with the largest loads and the line in the pilot. More meters can be added later on the same data model.

Can you use our existing meters?

Often. Meters with a Modbus interface or a pulse output can usually be read, and we check each one during the equipment and data survey.

Can this support ISO 50001 or 50001 Ready?

ISO 50001 is a standard for an energy management system (EnMS), built on the same continual improvement model as ISO 9001 and ISO 14001; ISO itself “does not perform certification.” DOE’s 50001 Ready program recognizes facilities and organizations that attest to implementing an ISO 50001-based energy management system. DOE describes it as “a self-paced, no-cost way” to do that, one that “does not require any external audits or certifications.” Measured energy by line, shift and product is one input such a system uses. The management system itself, with its policy, objectives and reviews, is yours. OpenGXT does not certify or attest to anything.

Can it feed our customer’s emissions questionnaire?

The software exports measured energy use by period, site and line in open formats. Converting energy into emissions and reporting them is work for your team or your adviser; we do not calculate carbon figures.

Example (fictional). On a fictional beverage bottler’s Line 2, the line’s electricity meter records 620 kWh for the 480-minute first shift (a fictional figure). The filler made 40,580 good bottles, so energy per good unit is 620 ÷ 40,580 = 0.0153 kWh, or 15.3 kWh per 1,000 good bottles. In the 105 minutes the filler was not running (the 30-minute break and 75 minutes of stops), the line still drew 70 kWh, 11.3% of the shift’s electricity, while making nothing. On a fictional Sunday with no production, the Line 2 compressed-air flow meter reads 14 cfm. That goes into the leak log as the baseline; after repairs the same reading is taken again. Try the electricity and gas figures for a whole site in the energy per unit calculator.

What you provide and what you receive

You provide You receive
Recent utility bills A metering plan
A single-line diagram or panel schedule Energy dashboards by site, line and meter
A list of existing meters Energy per unit by line and shift
Production counts, or production monitoring on the same line A compressed-air baseline and leak log
Electricians or a contractor for any new meters A data dictionary with every formula and conversion

Where to start

Start with the line you are piloting and the utilities that cost the most, usually electricity and compressed air. Read more about energy and throughput in The Plant Data Journal’s production performance articles, or plan a pilot line with energy in scope from the first shift.

Start with one line.