Energy per unit calculator for electricity and gas
The energy bill says how much the plant used. Energy per good unit says whether making each unit is getting cheaper.
For: Energy managers, plant managers and operations finance

Calculator
A rising energy bill can mean the plant is wasting more, or simply that it made more. Energy per good unit separates the two. It divides the energy used in a period by what the plant produced in the same period, so a busy month and a quiet month can be compared on the same footing. The calculator above does this for electricity and natural gas, combines them in one unit, and adds the cost.
How the calculator works
| Result | Calculation |
|---|---|
| Electricity per unit | kWh ÷ good units |
| Natural gas per unit | Therms ÷ good units |
| Total site energy | kWh × 3.412 + therms × 100, in kBtu |
| Energy per unit | Total kBtu ÷ good units |
| Energy cost for the period | kWh × electricity price + therms × gas price |
| Energy cost per unit | Energy cost ÷ good units |
The conversion factors are the ones published by the U.S. Energy Information Administration: 1 kilowatthour = 3,412 Btu and 1 therm = 100,000 Btu. Converting both to kBtu lets you add electricity and gas into one figure. This is site energy, the energy delivered to the plant, not the fuel burned at the power station to make the electricity.
Example (fictional). A fictional food plant uses 186,000 kWh of electricity and 4,200 therms of natural gas in one month, and ships 520,000 good units. It pays $0.085 per kWh and $0.92 per therm.
- Electricity per unit: 186,000 ÷ 520,000 = 0.3577 kWh
- Natural gas per unit: 4,200 ÷ 520,000 = 0.00808 therms
- Total site energy: 634,632 kBtu from electricity (186,000 × 3.412) plus 420,000 kBtu from gas (4,200 × 100) = 1,054,632 kBtu
- Energy per unit: 1,054,632 ÷ 520,000 = 2.028 kBtu
- Energy cost: $15,810 for electricity plus $3,864 for gas = $19,674
- Energy cost per unit: $0.0378
Electricity is about 60% of the energy in kBtu but about 80% of the cost, so it is where a kWh saved is worth most here.
Collecting good inputs
- Match the periods. Utility bills often run between meter read dates, not calendar months. Use the same dates for energy and production, or use interval meter data that can be cut at midnight.
- Count good units only. Rejects used energy too, but counting them as output hides the waste. If you make several products, choose one common unit (cases, kilograms, parts) and keep it.
- Use therms from the bill. Gas is metered by volume and usually billed in therms after a heat content factor is applied. The therm figure already includes it.
- Price. A blended price (the bill total divided by the kWh billed) includes demand charges and fees. If you want to value a saving, ask whether it reduces kWh, peak demand or both.
- Scope. If the energy is the whole plant, the units should be the whole plant’s output. One line’s energy needs a sub-meter on that line.
Reading the result
Compare periods with similar product mix and weather, or normalize for them. Heating, cooling and refrigeration loads follow the weather, and different products need different energy.
Then look at baseload: the energy the plant uses when it makes nothing, such as nights, weekends, lighting, compressors holding pressure and HVAC. Baseload makes energy per unit rise in low-volume months even when nothing is wrong. Plot each month’s energy against its output: the point where the line crosses zero output is roughly your baseload, and the slope is the energy each extra unit really needs.
Energy per unit is the kind of measure an energy management program tracks over time. ISO 50001 helps organizations “improve energy use, through the development of an energy management system (EnMS)”, and the U.S. Department of Energy’s 50001 Ready program is “a self-paced, no-cost way” to put an ISO 50001-based system in place. If you are working toward either, energy per unit is a natural candidate for the measures you track.
Common mistakes
- Dividing plant energy by one line’s output. The answer is meaningless. Match the meter to the output.
- Comparing winter with summer directly. Normalize for weather or compare the same month year over year.
- Ignoring baseload. Cutting weekend load can save more than tuning a line that runs only a few hours.
- Mixing site and source energy between periods or between plants.
From the monthly bill to every shift
Energy monitoring reads electricity meters, gas meters and compressed air flow, and divides them by the good count from the same line, so energy per unit appears per shift, per line and per product. Compressed air is often the easiest saving to find; the compressed air leak calculator shows what leaks cost. Rejects carry energy too, which is one more reason to look at quality in the OEE calculator. For refrigerated sites, see cold storage.
Start with one line.
Tell us which line you want to understand and the question you ask after every shift. We reply with questions or a time to walk it with you.