OpenGXT homePlan a pilot line
Menu

Setting ideal cycle time so OEE performance stays honest

The reader questionWhich ideal cycle time should we use for OEE performance: nameplate, best demonstrated or a standard rate?

A small yellow toy pace car leading a row of evenly spaced boxes along a green conveyor, watched by a tiny worker in a flat cap.

Use as the ideal cycle time the fastest rate the machine is designed to run, or has proven it can sustain, for that specific product in its installed setup, whichever is faster, and write down the source for each product. Do not use the standard or budget rate that planning uses, and do not use the average: both are slower than the machine can run, so they hide speed losses and can push performance above 100 percent. A builder’s nameplate maximum is only a valid ideal when it applies to the product and format you are running. If performance ever comes out above 100 percent, the ideal is set too slow and must be corrected, not capped.

That is the rule our OEE calculator applies: its ideal rate input asks for “the fastest rate the line is designed or proven to sustain”, and it flags any performance above 100%. The sections below compare the candidate rates on one fictional shift, show how to derive the best demonstrated rate from machine count data instead of a stopwatch, set out how to version ideal cycle times when tooling or product changes, and separate ideal cycle time from takt time and effective machine cycle time.

What ideal cycle time does in the OEE formula

Ideal cycle time sets the yardstick for the performance factor and for nothing else. Availability is calculated from minutes and quality from counts; performance compares what the machine made while it was running with what it would have made at the ideal. Change the ideal by 5% and performance, and OEE with it, changes by about 5%.

The Lean Enterprise Institute describes the performance rate as measuring “operating speed losses”, which it defines as running at speeds lower than design speed and stoppages lasting a few seconds. The OEE.com calculation page gives the formula: performance = (ideal cycle time × total count) ÷ run time. Because rate is the reciprocal of time, the same factor can be written as (total count ÷ run time) ÷ ideal run rate.

  • Ideal cycle time is time per unit: 0.5 seconds per bottle, 12.0 seconds per shot, 5.6 minutes per part.
  • Ideal run rate is units per time: 120 bottles per minute. It is the same number inverted. OEE.com’s glossary defines ideal cycle time, “also known as Design Cycle Time”, as “the theoretical minimum time to produce one part.”

Example (fictional). The Line 2 filler at a fictional beverage bottler has an ideal rate of 120 bottles per minute, an ideal cycle time of 0.5 seconds. On one first shift it runs for 375 minutes and fills 41,212 bottles. At the ideal, 375 minutes would have produced 45,000 bottles, so performance is 41,212 ÷ 45,000 = 91.6%. Converted to time, the 41,212 bottles needed 343.4 minutes at the ideal rate, so 31.6 minutes of the run time were lost to slow running and short stops. These are the default values in the OEE calculator.

Units that trip people up

Most errors in the ideal field are unit errors, not judgment errors. Four checks catch nearly all of them:

  • Time or rate. An ideal of “120” means nothing until someone writes “bottles per minute” or “seconds per case” beside it. Store both forms, ideal cycle time and ideal rate, and check that one is the inverse of the other.
  • Per minute or per hour. A rate of 7,200 per hour is 120 per minute. Software that expects one and receives the other is off by a factor of 60.
  • Per cycle or per unit. A press that makes four parts per stroke, a filler with twelve valves, a molding tool with eight cavities: the ideal must be expressed in the same unit as the count. If the count is parts, the ideal is parts per minute, which is strokes per minute times parts per stroke.
  • Primary or secondary packages. A case packer counts cases; the filler upstream counts bottles. The ideal on each machine must use the unit its own counter uses.

The number in the ideal field therefore decides how many minutes of slow running the shift report can see. Set it too slow and those minutes vanish. Set it to a speed the machine cannot reach for this product and the report shows a loss nobody can recover. The rest of this article is about choosing a value between those two errors and writing down how you chose it.

Four candidates: nameplate, design speed, best demonstrated and standard

Plants usually have four or five numbers that could go in the ideal field, and each comes from a different document and serves a different purpose. Only two of them belong in OEE.

Candidate What it is Where it comes from Use for OEE?
Nameplate or brochure maximum The top speed the builder quotes, often for the easiest format Machine builder’s specification Only if it applies to this product and format
Design speed for this product The speed the machine is designed to run for this format in its installed setup Builder’s documentation, acceptance test, or the PackML MachDesignSpeed tag Yes
Best demonstrated sustained rate The highest rate the machine has held over a defined window for this product Machine count data Yes, if faster than the design speed
Standard or budget rate A planning rate with allowances for expected losses Planning, costing or quoting No
Average actual rate Total count divided by run time The shift report No

Nameplate and design speed

OEE.com’s FAQ and its practical OEE page name two ways to determine ideal cycle time. The first is nameplate capacity, “the value that the equipment builder specifies (e.g., you may buy a press with a design capacity of 120 strokes per minute).” The second is a time study, discussed below.

The weakness of nameplate is that it is often quoted for the most favorable product. A cartoner rated at 150 cartons per minute may reach that on its smallest carton and run a large carton far slower by design. PackML makes this distinction explicit. The OPC Foundation’s OPC UA for PackML specification defines a tag, MachDesignSpeed, as “the maximum design speed of the machine in primary packages per minute for the package configuration being run”, and adds: “This speed is NOT the maximum speed as specified by the manufacturer, but rather the speed of the machine is designed to run in its installed environment.” Where a machine publishes that tag, it is the best documented starting point there is.

Best demonstrated rate

The second OEE.com method is a time study that measures “the absolute fastest speed that the process can support (not an average, normal or sustained speed).” Our calculator asks for a slightly different value: the fastest rate the line is designed for or has proven it can sustain. The difference is deliberate. A single fast cycle can be a counting artifact, such as a burst of accumulated product released after a jam, and a rate that lasted for 20 seconds is not one anyone can plan improvement around. A rate held for a defined window, at normal quality, is one the machine has shown it can do. If your plant prefers the strict theoretical maximum, document that choice; what matters is that the rule is written down and applied to every product.

Standard and budget rates

OEE.com’s FAQ is blunt about planning rates. Standard cycle time “includes allocations for typical losses including planned stops, unplanned stops, small stops, slow cycles, and defects”, so that planners can schedule with confidence. Asked whether to use it for OEE, the FAQ answers “Definitely not”, because it hides losses, and warns that operators may set their equipment to run at the standard rate. Its advice: “Use Ideal Cycle Time to measure OEE. Keep Standard Cycle Time off the factory floor.”

A note on words: some plants call the mold’s or the program’s rated cycle its “standard cycle”. That is a naming habit, not a planning rate. What matters is whether the number includes allowances for losses. If it does, it is a planning rate and does not belong in OEE.

How each choice changes the same shift’s performance

The same shift, with the same counts and the same run time, can report performance anywhere from about 70% to above 100% depending on which candidate goes into the ideal field. Nothing about the machine changes; only the yardstick does.

Example (fictional). The Line 6 cartoner at a fictional contract packager runs a 12-count carton. On one shift it has 400 minutes of run time and packs 41,600 cartons, 41,100 of them good. The plant has five numbers it could use as the ideal rate:

Candidate Rate Performance Minutes lost to slow running
Builder’s brochure maximum (all formats) 150 per min 69.3% 122.7
Design speed for the 12-count carton 130 per min 80.0% 80.0
Best demonstrated, highest 15-minute run-only window in six weeks 126 per min 82.5% 69.8
Average running rate this shift 104 per min 100.0% 0
Standard rate used by planning 95 per min 109.5% none (negative)

Following the rule, the plant uses 130 cartons per minute: the faster of the design speed for this carton (130) and the best demonstrated rate (126). Performance is 80.0% and the shift report shows 80 minutes of slow running and short stops. About 70 of those minutes are the gap to what the cartoner has already done; the other 10 are the gap between what it has done and what it was designed to do, a question for the controls engineer and the machine builder.

Performance for one shift under five ideal rates Brochure maximum, 150/min Design speed, 130/min (used) Best demonstrated, 126/min Average running, 104/min Planning standard, 95/min 69.3% 80.0% 82.5% 100.0% 109.5% 0%50%100% Red: above 100%, so the ideal is set too slow. Dark green: the rate the rule selects.
Fictional example data: one shift on a fictional contract packager's Line 6 cartoner, 400 minutes of run time and 41,600 cartons, calculated with the performance formula on OEE.com's calculation page.

The choice also changes the size of the prize the report points at. At 130 cartons per minute, 80 minutes of slow running is 10,400 cartons of capacity on one shift. At the planning standard the same shift shows no capacity to recover at all. A plant deciding between a second shift and a speed improvement project needs the first answer, not the second.

Two rows deserve a closer look. Using the average running rate always produces exactly 100% performance, because the ideal then is the actual. Every slow cycle and every short stop disappears, which makes the number useless. Using the planning standard produces more than 100%, which is impossible: the line cannot make more than it could make. Both are common in plants that set up OEE from the scheduling system’s rate table.

The sanity rule: performance above 100 percent

Performance above 100% always means a definition or a measurement is wrong, and the ideal cycle time is the usual culprit. The OEE.com calculation page says performance “should never be greater than 100%. If it is, that usually indicates that Ideal Cycle Time is set incorrectly (it is too high).” Too high, in time per unit, is the same as too slow in units per minute. Our calculator prints a note whenever performance exceeds 100%: the ideal rate is set lower than the line actually runs.

What to check, in order

  1. The ideal is a planning rate or an old value. The most common cause. Look up where the number came from; if nobody knows, that is the answer.
  2. The wrong product’s ideal is applied. The line changed over to a faster format and the product code on the run did not change. Check the product on the run record against what was actually made.
  3. The count is taken at the wrong point or with the wrong unit. Counting bottles at the filler but applying an ideal in cases, or a counter that increments twice per cycle. Compare the count with the machine’s own counter on the HMI for a known run.
  4. The cavitation or units per cycle is wrong. On a press, an ideal per shot multiplied by the wrong number of cavities. On a multi-lane machine, lanes added without updating the ideal.
  5. Run time is too short. A stop counted twice, or excluded time that overlaps a period when the machine was running, shrinks run time and inflates performance. Check that state durations add up to the shift.

Never cap it

Some reporting tools cap performance at 100% so the number looks sensible. That hides the signal. A performance of 104% is information: the ideal is at least 4% too slow, and every shift on that product has been reporting less slow running than it had. Fix the ideal, record the change and note the step in the trend.

Example (fictional). Suppose that someone entered 100 bottles per minute, a planning rate, as the ideal for the Line 2 filler instead of 120. The same shift would show performance of 41,212 ÷ (100 × 375) = 109.9%, and the OEE calculator would flag it. The filler did not run faster than possible. The ideal was 17% too slow, and the 31.6 minutes of slow running on that shift had disappeared from the report.

Deriving the best demonstrated rate from machine data

Derive the best demonstrated rate from the machine’s own count signal over several weeks, using windows of steady running, not from a stopwatch study on one afternoon. The Lean Enterprise Institute defines cycle time as the time required to produce a part or complete a process “as timed by actual measurement.” Machine data is actual measurement of every cycle on every shift, with nobody standing beside the machine.

A stopwatch study has two weaknesses. It samples a few dozen cycles on one day, usually on the shift with the best operator. And the people being timed know it, which can push the rate either way. Count data from the controller covers weeks, every shift and every crew, and it can be filtered to the windows that matter.

The procedure

  1. Use the same counter that feeds OEE, at the machine OEE is measured on, usually the constraint. A rate measured at a different point is a different rate.
  2. Pull the count at one-minute resolution or finer for a reference period of four to eight weeks, separately for each product or format.
  3. Keep only steady running. Drop every minute inside a stop longer than your reason threshold, and the first few minutes after any stop or changeover, so start-up does not drag the rate down.
  4. Compute rates over rolling windows long enough to mean something. On a fast packaging machine, 10 to 15 minutes is several thousand units. On a machining cell with a 5-minute cycle, use part-to-part times for ten or more consecutive parts instead.
  5. Take the highest window and check its quality. The window counts only if its reject rate was normal for the product. A fast window with high rejects is not a rate the machine can sustain.
  6. Check it with the controls engineer. Confirm that no speed limit, recipe parameter or interlock was changed during the window, and compare its count with the HMI counter.
  7. Compare it with the design speed for the same product and use the faster of the two.
  8. Record the value, the window, the evidence and the approver in the data dictionary.

Highest window or a percentile

Taking the single highest window is the simplest rule and the closest to OEE.com’s fastest-speed advice. A more conservative alternative is a percentile rule, for example the rate that only the top 10% of windows exceeded. It is less sensitive to one unusual window, but it builds some speed loss into the ideal by design. Neither rule is a standard: the Lean Enterprise Institute’s definition refers to design speed, and OEE.com’s methods are nameplate capacity and a time study of the fastest speed. Pick one rule, write it in the data dictionary and use it for every product.

Products that rarely run

A product that runs twice a quarter will not give you enough steady windows to trust. Use its design speed if the builder can state one for that format. If not, start from the demonstrated rate of the closest format in the same family, mark the ideal as provisional, and replace it after a set number of runs. A provisional ideal with a note is better than a blank, because a blank tends to be filled with the planning rate.

Why not the speed tag

Many machines publish a speed value. PackML has two: MachSpeed, the setpoint speed, and CurMachSpeed, the current speed, as the OPC 30050 specification describes them. The setpoint is what someone asked for, not what the machine delivered. The current speed describes the mechanism, not the product: the specification allows a machine in the Suspended or Held state to dry cycle, moving without producing. Rates calculated from the production count are harder to fool. Use the speed tags to explain a window, not to define the ideal.

15-minute run-only windows, one carton size, six weeks 6143146382293 Shift average 104 Best sustained 126 Design speed 130 Fastest single minute 141 95100105110115120125130135140145 Cartons per minute (each bar is a 4-carton bin; number of windows above each bar)
Fictional example data: 169 windows of 15 minutes with no stop over the reason threshold, from the same fictional Line 6 cartoner. The fastest single minute came from accumulated cartons released after a jam was cleared, so it is not used.

The histogram shows why the window matters. Most steady running sits between 104 and 120 cartons per minute. Three windows reached 124 to 128, and the highest held 126 for a full 15 minutes at normal quality: that is the demonstrated rate. One single minute counted 141 cartons because the cartoner discharged a backlog after a jam; using it would set an ideal the machine has never actually sustained and would make every shift look worse than it was.

One ideal per product, format and machine

Every product, format or part program that runs at a different speed needs its own ideal, applied to the counts made while it ran. A single ideal for the whole line is only correct if every product genuinely runs at the same speed. PackML ties the design speed to “the package configuration being run” for this reason.

Mixed runs in one shift

When a shift runs two products with different ideals, calculate each run separately and combine the times, not the percentages. The OEE.com FAQ gives the formula: performance = Σ(ideal cycle time × total parts) ÷ Σ run time, with each sum taken across every product run. The OEE calculator page gives the equivalent manual method: convert each product’s count to minutes at its own ideal rate and add the minutes. A simple average of each product’s performance gives a short run the same weight as a long one.

Molds, cavities and part programs

  • Injection molding. The ideal is per mold, and per shot. Parts follow from shots times cavities. Keep the ideal at full cavitation, so a blocked cavity shows as lost output rather than vanishing. Our page on plastics and packaging plants works through a fictional press where a blocked cavity cost three times as many parts as a slow cycle; that comparison only exists because the yardstick stayed at full cavitation.
  • CNC machining. The ideal is per part program, measured part-to-part on the machine OEE is calculated on. A quoted cycle is a costing number; the fictional VMC on our machine shops page was quoted at 6.0 minutes and averaged 6.5, and neither figure is its ideal.
  • Packaging. The ideal is per format: carton size, bottle size, pack count. A size change starts a new run with a new ideal.

Where to measure

Set the ideal for the machine OEE is measured on. The OEE.com FAQ recommends measuring OEE at the constraint, because “the performance of your constraint IS the performance of your line.” An ideal set for the fastest machine on the line, while the constraint is a slower one, will show a speed loss that no work on the constraint can recover.

Sometimes the constraint moves with the product: the filler limits one bottle size and the labeler limits another. The FAQ’s answer is that it is correct in theory to move the measurement point, but to weigh the cost and complexity of doing so and “keep things simple.” In practice that means recording, for each product, which machine OEE is measured on and which ideal applies there, in the same data dictionary entry.

Versioning ideal cycle times when tooling or product changes

Treat each ideal cycle time as a versioned record with an effective date, a basis and an approver, and store the ideal that applied on every production run. Then a change never rewrites history: last quarter’s performance stays calculated against last quarter’s ideal, and the trend shows a marked step where the yardstick moved.

What justifies a change

Change Direction Action
A demonstrated rate beats the current ideal over the defined window Faster New version of the same product’s ideal
Performance above 100% on the product Faster Correct immediately, then investigate how it happened
New tooling, change parts or a controls upgrade that raises design speed Faster New version, with the builder’s or engineer’s document
A new carton, bottle, mold or program with a different design speed Either A new product or format record, not a new version
Machine age, wear or a poor batch of material None Keep the ideal; the loss is real and worth fixing
A short crew when demand is full None Keep the ideal; record the reason
A bad month None Keep the ideal

The “none” rows come from OEE.com. Its FAQ says the ideal “should generally NOT be lowered due to factors such as machine age or material quality”, because those losses “should be mitigated using Lean Manufacturing, Six Sigma, and other improvement tools.” On a short crew, it advises that when there is full customer demand you should “not change the Ideal Cycle Time.”

The one case for a slower ideal is a real change in what the machine is making. A heavier carton board that the builder rates at a lower design speed is a new format with its own ideal. It is not a reason to lower the ideal for the old carton.

Product characteristics versus material problems

The line between those two cases needs care, because it is where most arguments about the ideal happen. A filler that runs still water at 120 bottles per minute may be designed to run a highly carbonated product more slowly, because the product foams at higher speed. That is a property of the product as specified, documented by the builder or by a controlled trial, and it justifies a separate ideal for that product. A batch of preforms that runs badly because it is out of specification is a material problem. It is exactly the kind of loss OEE should show, and the ideal stays where it is. The test is whether the lower speed would still be needed if every input met its specification. If it would, it belongs to the product. If not, it belongs on the loss report.

Who owns the ideal

Give the ideal an owner and an approver, and keep it off the operator’s screen. A workable split is that a continuous improvement or process engineer proposes changes with evidence, the controls engineer confirms that the machine’s settings support the new rate, and the production manager approves. Operators and supervisors should be able to see the ideal that applies to the current run, but not edit it. An ideal that can be changed from the shift board drifts toward whatever makes the shift look good.

What each version records

Example (fictional). The data dictionary entry for the Line 6 cartoner’s 12-count carton has three versions. Version 1, effective from week 1, sets 118 cartons per minute, the best 15-minute window in the first six weeks of data, because no design speed document could be found. Version 2, effective from week 11, sets 126 per minute after a set of new infeed lugs was fitted and the best window rose; the evidence is the window’s start time and count. Version 3, effective from week 20, sets 130 per minute after the machine builder confirmed in writing the design speed for this carton size in this installation. Each version names the approver and keeps the previous value. The shift reports from weeks 1 to 10 still show performance against 118, and the trend chart marks weeks 11 and 20.

Each version should hold: the product or format code, the machine, the ideal (as both cycle time and rate, so nobody inverts it by mistake), the basis (design speed document, demonstrated window or both), the evidence, the effective date, the approver and the version it replaces. Review every ideal at least once a year, and whenever a product shows performance close to 100% for several weeks, which usually means the machine has quietly learned to run faster.

Keeping these records is part of the documentation we hand over with every system: the production monitoring data dictionary lists each product’s ideal rate next to the OEE formula, and changes go through the same change log as the reason codes.

Ideal cycle time, takt time and effective machine cycle time

Ideal cycle time describes what the machine can do; takt time describes what the customer needs; effective machine cycle time describes what the machine delivers once loading and changeovers are spread over the parts. They answer different questions and should never be substituted for one another.

The Lean Enterprise Institute’s lexicon defines each term:

  • Takt time is “the available production time divided by customer demand.” Its example: a plant that works 480 minutes a day with demand for 240 widgets a day has a takt time of two minutes.
  • Cycle time is “the time required to produce a part or complete a process, as timed by actual measurement.”
  • Machine cycle time is “the time a machine requires to complete all of its operations on one piece.”
  • Effective machine cycle time is machine cycle time plus load and unload time, plus changeover time divided by the number of pieces between changeovers. LEI’s example: a 20-second machine cycle, 30 seconds to load and unload, and a 30-second changeover over a batch of 30 gives 20 + 30 + 1 = 51 seconds.
Term Set by Includes Used for
Ideal cycle time The machine’s design or demonstrated capability Nothing but the cycle itself, at its best sustained pace OEE performance
Machine cycle time The machine, as measured One piece’s operations Balancing, comparing with takt
Effective machine cycle time The machine plus its handling and changeover Load, unload and a share of changeovers Capacity at a given batch size
Standard cycle time Planning Allowances for typical losses Scheduling, costing, quoting
Takt time Customer demand and available time Nothing about the machine Pacing the line to demand

Why takt is not an ideal

Takt changes when demand changes; a machine’s capability does not. If the ideal were set to takt, performance would rise and fall with the order book. Our takt time calculator shows the right relationship: in its fictional default example, 900 available minutes and demand of 1,800 units a day give a takt of 30.0 seconds, and a slowest station at 27 seconds can keep pace with 3.0 seconds to spare. That comparison is about capacity against demand. OEE asks a different question: how close did the station come to its own best?

OEE.com’s practical OEE page offers a useful way to use both numbers. For operators, it suggests an efficiency measure, “the ratio of Good Count to Target Count”, calculated from takt time, so operators can “win their shift”, while “management keeps their focus on the true capabilities of the process based on Ideal Cycle Time.” The two numbers live side by side and are never merged.

Why effective machine cycle time is not an ideal

Effective machine cycle time includes a share of each changeover. In OEE, changeovers already count against availability. Using the effective time as the ideal would count the same changeover minutes a second time, inside performance, and would make the ideal depend on batch size. Use the effective time for capacity planning at a given batch size. How changeovers and other planned events enter OEE is covered in our article on planned downtime in OEE.

Short stops and the ideal

Short stops below the reason threshold land in performance, alongside slow cycles. An ideal that is too slow can hide them entirely, because the minutes lost to short stops are offset against cycles that look faster than the ideal. If your performance loss looks large and nobody can see the line running slowly, the cause is usually a run of short stops, which the machine can count by fault code. Our companion article on manual and automatic downtime tracking covers how each tracking method catches them.

Checklist for setting and documenting ideal cycle times

Work through this list for one line before its first OEE report, then repeat it whenever a new product or format is introduced.

Setting the value

  • Name the machine OEE is measured on, usually the constraint, and the counter that feeds the good and total counts.
  • List every product, format, mold or program that runs on it at a different speed.
  • For each, find the design speed for that product in this installation: the builder’s documents, the acceptance test or the PackML MachDesignSpeed tag.
  • For each, derive the best demonstrated rate from four to eight weeks of count data, using steady-running windows and checking quality in the best window.
  • Use the faster of the two. Do not use the standard rate, the quoted cycle, the average or takt time.
  • Enter both the ideal cycle time and the ideal rate, and check that one is the inverse of the other.

Running with it

  • Flag any shift with performance above 100% and correct the ideal, never cap the result.
  • Keep the ideal on every production run record, so history is never recalculated.
  • Version every change with its basis, evidence, effective date and approver.
  • Lower an ideal only when the product or format genuinely changes, and then as a new record.
  • Review every ideal at least once a year, and sooner when a product runs close to 100% for weeks.

To see how the ideal moves the result on your own line, enter one shift into the OEE calculator with each of your candidate rates and compare the minutes lost to slow running. If you want each product’s ideal derived from machine data, documented and versioned on one line first, you can plan a pilot line.

Working on this at your plant?

If this article describes a problem on one of your lines, tell us about it. We start with one line, its signals and the question you ask after every shift.