For most motor-driven assets, vibration is the first signal to monitor. It is the most common predictive testing technique in NASA’s reliability-centered maintenance guide, and it covers the faults that end most motor and machine lives, starting with bearings. Motor current is the better first choice where you cannot reach the machine (a submersible pump, a sealed refrigeration compressor, an evaporator fan in a freezer) or where the faults you fear are electrical, such as broken rotor bars. On motors whose failure stops a line, use both: NASA’s guide lists motor current signature analysis as a way to “supplement vibration monitoring on critical motors.”
There is a third option that many plants overlook. If you meter electricity at the motor control center or read current from a drive, you already have a current signal. It is not a signature, but it tells you when the motor runs, how hard it works and how it starts. For assets that do not justify a sensor of their own, that is often enough.
This article compares the two signals fault by fault, explains why load and variable-frequency drives distort both, works through fans, pumps, conveyors and compressors one at a time, and ends with a checklist. It is written for maintenance and reliability engineers and for facility managers in plants, distribution centers and cold storage. Which assets deserve monitoring at all is a separate question, covered in our guide to ranking equipment criticality in a small plant.
What vibration and motor current actually measure
Vibration monitoring measures how a machine moves around its rest position. Motor current monitoring measures how much current the motor draws, and how that current changes from one cycle to the next. Both are indirect: neither sees a cracked bearing race, but both can see what the crack does to the machine.
Vibration
NASA’s Reliability-Centered Maintenance Guide for Facilities and Collateral Equipment (September 2008) defines machinery vibration as “the periodic motion of a body about its equilibrium position” and calls vibration monitoring “the most common PT&I technique,” where PT&I means predictive testing and inspection. A sensor, usually an accelerometer, sits on or near a bearing housing and reports the motion as displacement, velocity or acceleration. The U.S. Department of Energy’s Operations and Maintenance Best Practices Guide, Release 3.0 (August 2010, prepared for the Federal Energy Management Program) defines the three: displacement is the total distance traveled, velocity is how fast the part moves, and acceleration is the rate of change of velocity.
The reading comes in two forms, and the difference decides what you are buying:
- Overall value. One number that sums the vibration energy across a frequency band. NASA’s guide says an overall measurement “does not provide a complete analysis of a systems condition” and that a modern program “shall not depend solely” on it. Its appendix rates overall readings as a pass or fail check, “not recommended except for low cost/low risk equipment.”
- Spectrum. The same signal split into frequencies with a fast Fourier transform (FFT). Each fault leaves energy at its own frequencies: once per revolution for unbalance, at bearing defect frequencies for a damaged bearing, at gear mesh frequency for a worn gear. NASA calls spectrum analysis “the most common analysis method for machinery diagnostics.”
Motor current
An induction motor turns current into torque, so anything that changes the torque the load demands shows up in the current. The DOE guide puts it this way: the motor “acts as a transducer,” converting mechanical load variations “into electric current variations that are transmitted along the motor power cables.”
Current data also comes in three levels, and plants often mix them up:
- RMS current. One value per phase, averaged over a cycle or longer. Panel meters, motor protection relays and most drives report it. It tells you whether the motor runs and roughly how loaded it is.
- Current trend. RMS current logged over time next to the machine’s state and speed. A slow climb at the same throughput means the load is working harder.
- Current signature. The raw current waveform, sampled thousands of times per second and turned into a spectrum. This is motor current signature analysis (MCSA), which NASA’s guide describes as “a remote, non-intrusive, on-line method of testing motor-driven equipment.”
Do not confuse MCSA with motor circuit analysis. NASA describes motor circuit analysis as a test on a de-energized motor that measures resistance, capacitance and inductance to find winding and insulation problems. It is a useful test, but it happens during a planned stop. It is not a signal you can stream.
Both methods have a long public record. PNNL’s summary of maintenance approaches, drawn from the same DOE guide, lists “Vibration analysis” and “Motor analysis” among the traditional predictive maintenance technologies, next to thermography, oil analysis, ultrasonic analysis and performance trending.
What each signal can detect
Vibration covers mechanical faults in both the motor and the driven machine. Current signature analysis is strongest on the motor’s own rotor and air gap and can see some driven-machine faults. RMS current sees only changes in load. The table compiles what the public guides list for each method.
| Fault or condition | Vibration spectrum | RMS current trend | Current signature (MCSA) |
|---|---|---|---|
| Rolling element bearing damage | Primary method | Late, if friction raises load | Listed in research literature; less established |
| Unbalance | Primary method | No | Listed by DOE (rotor balancing) |
| Misalignment | Primary method | Indirect (higher load) | Listed in DOE and research literature |
| Mechanical looseness, resonance | Primary method | No | Not listed in these sources |
| Belt, sheave and pulley flaws | Primary method | Belt slip lowers load | Not listed in these sources |
| Gear damage | Primary method | No | Listed by DOE (gear wear); needs expert analysis |
| Cavitation, flow turbulence | Listed by NASA | Load change | Not listed in these sources |
| Broken rotor bars, cracked end rings | Possible (slip sidebands) | No | Primary method |
| Air gap eccentricity | Listed by DOE (eccentric rotors) | No | Primary method |
| Stator winding and insulation faults | No | No | Listed in research literature; offline tests (surge, motor circuit analysis) are the reference |
| Process load change (clogged filter, jam, worn impeller) | Sometimes | Yes, the main use | Yes |
Three points from the sources deserve emphasis.
First, bearings come first for a reason. DOE’s Motor Systems Tip Sheet #3 (November 2012) says bearing failures “account for nearly two-thirds of all motor failures.” The 2010 O&M guide puts the share at “nearly one-half.” The two DOE documents disagree on the number but agree on the order: bearings are the largest single cause. The tip sheet names “vibration trending and thermal scanning” as the ways to catch bearing problems before they damage the winding.
Second, MCSA has a real and specific strength. NASA’s guide lists broken rotor bars or high resistance joints, defective rotor shorting rings, rotor and stator (air gap) eccentricity and unbalanced magnetic pull as faults MCSA “may be used to detect.” These are faults inside the motor that a sensor on the housing sees only indirectly. A research paper on broken rotor bar detection by Hajnayeb and colleagues, posted as an accepted manuscript in the University of Essex repository, adds that MCSA can also analyze cracked end rings, stator faults, misalignment and bearing failures, citing earlier work. Treat that wider list as possible with skilled analysis, not as a replacement for vibration.
Third, neither method interprets itself. The DOE guide says vibration signature analysis “requires highly trained and skilled individuals.” It calls MCSA moderately complex, partly because of “the relatively subjective nature of interpreting the spectra” and the limited number of reference spectra available for specific applications. Buying sensors does not buy diagnosis. Plan for the analyst, in house or contracted, before you plan the hardware.
Where temperature fits
Temperature is the third signal worth naming, because it is cheap and often already measured. DOE’s tip sheet #3 states that “for every 10°C rise in operating temperature, the insulation life is reduced by half,” and lists dirt, voltage unbalance, harmonics, poor ventilation and overload among the conditions that cause overheating. A winding temperature from a motor protection relay, or a bearing housing temperature from a simple sensor, catches cooling and overload problems that neither vibration nor current isolates well. For bearing damage it is a late indicator. NASA’s appendix pairs it with vibration, noting that “high temperature & high vibration level are indicative of imminent failure.” Use temperature as a supporting signal, not as the early warning.
Why load, speed and drives change both readings
Both signals change with the work the machine is doing, so a reading means little unless you know the load and speed at the moment it was taken. This is a common reason condition alerts get ignored: the number moved because the product changed, not because the bearing did.
Vibration depends on speed, load and mounting
NASA’s guide says vibration amplitude “varies with operating speed, load, and mounting arrangement.” It lists “complex, low speed (<120 RPM), variable speed, and reciprocating machinery” as “extremely difficult to monitor effectively.” ISO’s abstract of ISO 20816-3, the industrial machinery part of the vibration severity series, limits its criteria to measurements “under steady-state operating conditions within their nominal operating speed range.” A reading taken during a ramp, a product change or a half-speed run cannot be compared with one taken at full speed.
Current follows load, but not in a straight line
DOE’s fact sheet Determining Electric Motor Load and Efficiency gives the rule. The current a motor draws “varies approximately linearly with respect to load, down to about 50% of full load.” Below that point, because of the motor’s magnetizing current, the curve becomes increasingly nonlinear, and “current measurements are not a useful indicator of load.”
For the linear region, the same sheet estimates load as measured current divided by nameplate current, times measured voltage divided by nameplate voltage, times 100%. For example, suppose a motor with a 50 A nameplate draws 40 A at nameplate voltage: it is running at about 80% load. The practical lesson is the reverse case. A fan motor loafing at 30% load can lose a good share of its load, through a slipping belt or a closed damper, before its current says much.
Slip moves the current signature
For MCSA, load matters even more. A broken rotor bar shows up as two small peaks, called sidebands, on either side of the supply frequency. The Essex paper places them at the supply frequency times (1 ± 2s), where s is the slip: the fraction by which the rotor turns slower than the rotating magnetic field. The same paper names the main obstacle. The supply frequency peak is far larger than the fault peaks and can conceal them through spectral leakage. Slip shrinks as load falls, so at light load the sidebands crowd in against that large peak.
Example (fictional). A 4-pole induction motor on a 60 Hz supply has a synchronous speed of 1,800 rpm. At full load it runs at 1,764 rpm: slip is 36 ÷ 1,800 = 2%, and the sidebands sit at 60 × (1 ± 0.04), which is 57.6 Hz and 62.4 Hz, each 2.4 Hz from the supply peak. At light load the same motor runs at 1,794 rpm: slip is about 0.33%, and the sidebands sit at about 59.6 Hz and 60.4 Hz, only 0.4 Hz away. Frequency resolution is the inverse of the capture length. Separating a small peak 0.4 Hz from a large one needs a capture of 10 seconds or more (0.1 Hz resolution). A 1-second capture gives 1 Hz resolution, and the sidebands disappear into the supply peak.
This is why NASA’s acceptance specifications ask for the baseline motor current spectrum “on the loaded motor at 75 percent or greater load.” Take MCSA readings at a known, high load, and store that load with the reading.
Variable-frequency drives change the rules
A variable-frequency drive (VFD) does not pass the supply straight to the motor. DOE’s Motor Systems Tip Sheet #15 (November 2012) explains that all VFDs “rectify the 60-hertz (Hz) fixed-voltage alternating current (AC) to direct current (DC)” and then build a new adjustable-frequency output by fast switching, at a carrier frequency “usually between 2 kilocycles per second (kHz) and 20 kHz.” Three consequences follow for monitoring:
- Measure on the motor side. Because the drive rebuilds its output from a DC stage, a current transformer on the supply side sees the drive’s input current, not the motor’s signature. For signature work the sensor goes on the motor leads. For trending, read the drive’s own output current, frequency and fault codes over its communication port.
- The fundamental moves. The Essex paper notes that in inverter-fed motors “the fundamental frequency may vary within a very wide range,” and every fault frequency moves with it. The analysis has to follow the drive’s output frequency instead of assuming 60 Hz.
- Drives add a bearing failure mode. The same tip sheet warns that fast-switching drives can push current across the rolling elements of motor bearings and cause “bearing damage, called fluting.” That damage is mechanical and appears in vibration, one more reason vibration stays the first signal on drive-fed motors.
For both signals the rule is the same. Store the speed or drive frequency and the load next to every condition reading, and compare readings only within the same operating band.
Vibration severity zones, and why your own baseline matters more
Published severity zones help you judge an unfamiliar machine, but for monitoring, a change from the machine’s own baseline is the more useful signal. Many small-plant assets also fall outside the scope of the main industrial severity standard.
What the ISO 20816 series covers
The ISO 20816 series, “Mechanical vibration: Measurement and evaluation of machine vibration,” is replacing the older ISO 10816 and ISO 7919 parts. Parts 1 and 3, discussed here, replaced ISO 10816-1, ISO 7919-1, ISO 10816-3 and ISO 7919-3. The documents are sold by ISO, so this article relies only on ISO’s public abstracts and catalog entries. iso.org refused direct requests, so we read them through Internet Archive captures from October and November 2026.
- ISO 20816-1, the general guidelines, presents evaluation criteria “in terms of both vibration magnitude and change of vibration.” ISO’s catalog shows the 2016 edition withdrawn on October 28, 2026 and revised by ISO 20816-1:2026.
- ISO 20816-3:2022 covers industrial machinery “with a power rating above 15 kW and operating speeds between 120 r/min and 30 000 r/min,” measured in situ. Its scope includes electric motors with flexible couplings, conveyors, fans and blowers, and rotary compressors. The abstract says its numerical values “are intended to serve as guidelines based on worldwide machine experience, but shall be applied with due regard to specific machine features.” It replaced ISO 10816-3:2009, and in October 2026 ISO listed it as expected to be replaced within the coming months.
The exclusions matter more than the scope for a small plant. ISO 20816-3 does not cover rotodynamic pumps whose impeller sits on the motor shaft (it points to ISO 10816-7), rotary positive displacement compressors such as screw compressors, reciprocating machines or submerged motor-pumps. Its fan criteria are “generally only applicable to fans with power ratings greater than 300 kW or fans which are not flexibly supported.” It is based on broad-band readings and does “not address the diagnostic evaluation of the condition” of gears or rolling element bearings. A small conveyor gearmotor, a close-coupled process pump and a screw air compressor all sit outside it.
What the public guides say about limits
The DOE O&M guide shows an example severity chart and then warns that such values “are not absolute vibration limits above which the machine will fail and below which the machine will run indefinitely. It is impossible to establish absolute vibration limits.” It allows that, for a site without history, such charts “can serve as an excellent guide to get started.” This article does not reproduce zone values. They depend on the machine class, the mounting and the edition of the standard, and the current values are in the paid documents.
Build the baseline instead
NASA’s guide describes the alternative. Baseline data is condition data “representative of equipment in operating condition,” taken early in the equipment’s life and under similar conditions each time. It should be re-established “whenever equipment undergoes major maintenance, repair, or usage changes.” For alarms, the guide describes an alert at a statistically significant deviation from the mean, “usually 2-sigma,” and an alarm at 3-sigma. Both are then refined by comparing failed parts with the data that came before the failure.
Set expectations for warning time from the same source. NASA’s guide says narrowband vibration analysis “can warn of impending failure several weeks or months in advance,” and cites U.S. Navy studies with probabilities of detection “as high as 0.92 and as low as 0.76” and a false alarm rate of 0.08. Those figures describe an established program with trained analysts. Treat them as a ceiling to work toward, not as what a new sensor delivers in its first month.
Example (fictional). A cold storage warehouse logs the overall vibration velocity on an evaporator fan motor every 10 minutes, and keeps only the readings taken while the fan runs at its normal speed outside defrost. Over four weeks those readings give a mean, M, and a standard deviation equal to 12% of M. Following NASA’s method, the alert sits at M plus 2 sigma (124% of M) and the alarm at M plus 3 sigma (136% of M). These are this fan’s own statistics, not severity limits from any standard. When the motor is replaced or the fan rebalanced, the four-week baseline starts again.
The condition-based versus predictive maintenance article covers what to do with such alerts and how far a small plant should go beyond them.
Fans, pumps, conveyors and compressors: an asset-by-asset guide
The right first signal depends less on the motor than on the machine it drives and on whether you can reach it. The table summarizes the choice for the motor-driven assets most common in plants, distribution centers and cold storage. The sections after it explain the reasoning.
| Asset | First signal | Add on critical assets | Watch out for |
|---|---|---|---|
| Belt-driven fan (supply, exhaust, dust collection) | Vibration on fan and motor bearings | RMS current trend | Belt and sheave faults show in vibration; belt slip lowers current |
| Direct-drive fan on a VFD | Vibration, compared at the same speed | Drive output current and frequency | Drive-induced bearing currents |
| Evaporator fans in freezers and coolers | RMS current per fan or fan group | Route vibration during service windows | Defrost and ice change the load |
| Close-coupled centrifugal pump | Vibration at the motor bearings | Current trend against flow or pressure | Outside ISO 20816-3 |
| Frame-mounted pump with coupling | Vibration on motor and pump | MCSA if the motor is large or hard to replace | Misalignment after any coupling work |
| Submersible sump or well pump | Current: RMS, starts, run time | MCSA from the panel | Outside ISO 20816-3 |
| Conveyor gearmotor | RMS current from the drive or meter | Vibration on gearboxes that stop a main line or sorter | Low output speed makes gear diagnosis harder |
| Reciprocating air compressor | Current and temperature trends | Vibration trend at fixed points | NASA rates reciprocating machines hard to monitor by vibration |
| Rotary screw air compressor | Package controller data and current | Vibration route on motor and airend | Outside ISO 20816-3 |
| Hermetic or semi-hermetic refrigeration compressor | Current | Shell vibration trend | Motor sealed inside the compressor housing |
| Dock door and leveler motors | Cycle counts and peak current per cycle | Usually nothing more | Too few running seconds for vibration |
Fans and blowers
Fans are the clearest case for vibration. Unbalance from dirt buildup, worn bearings, loose mounts and belt problems all appear in the spectrum, and NASA’s list of conditions monitored by vibration includes “belt flaws” and “sheave and pulley flaws.” On a belt-driven fan, read both the fan bearings and the motor bearings, because the belt isolates one from the other.
Current earns its place on fans as a load signal. A slipping belt, a closing damper or a clogging filter all lower or raise fan load, and current tracks that above half load. A fan with large swings in airflow by design gives you a noisy current trend. Compare readings only at the same damper position or drive speed.
Freezer and cooler evaporator fans invert the choice. They hang in cold, iced coils where a technician spends as little time as possible, and a cold storage building may have dozens of them. Per-fan or per-group current from the motor control center tells you which fans run, which have stopped and which draw more than their neighbors. Route vibration readings can then go to the fans the current trend flags, during defrost or planned service. Our cold storage page describes the other signals in those buildings: temperatures, door openings and compressor runtime.
Pumps
On a frame-mounted pump with a flexible coupling, vibration on both the motor and the pump is the standard approach. Misalignment after coupling work, bearing wear and cavitation all appear there, and NASA lists “cavitation” and “flow turbulence” among the conditions vibration monitors. If the motor is large, slow to source or expensive to rewind, add MCSA for the rotor faults vibration sees poorly.
Close-coupled pumps, with the impeller on the motor shaft, are common in small plants and are outside ISO 20816-3. Monitor them by trend from their own baseline. A current reading taken next to a flow or discharge pressure reading tells you more than either alone. Falling current at the same valve position can mean a worn impeller, a closing suction strainer or air in the line.
Submersible pumps leave no choice: the motor is underwater. Current, starts per hour and run time per start are the condition signals, and all three can come from the pump panel. A sump pump that starts twice as often as last month is telling you about the inflow or the check valve, and a rising current per run can point to a worn or clogged impeller.
Conveyors, sorters and other distribution center drives
A large distribution center can run hundreds of small conveyor motors, many on drives, spread across a long building. Installing vibration sensors on all of them rarely makes sense. NASA’s guide says installed data collection sensors “may be justified for high-priority, high-cost equipment or inaccessible equipment,” and most small conveyor zones are none of those. The drives, however, already report output current, frequency and fault codes, and a gateway can read them over the drive’s network port. That gives a run signal, a load trend and a starts count for every zone at little extra hardware cost.
Put vibration where a failure stops the building: the main line drives, the sorter drive, the large gearboxes on spiral conveyors. Gear faults need vibration, and at the low output speeds of conveyor gearboxes that takes care; NASA notes that low-speed machinery is hard to monitor. Our page on distribution center equipment covers the other equipment signals in those buildings, from sorters to dock doors and chargers.
Air and refrigeration compressors
Screw air compressors usually come with a package controller that already reports discharge pressure, temperature, load and run hours. Read it first. ISO 20816-3 excludes rotary positive displacement compressors, so vibration on a screw compressor is a trend against its own history. A route reading on the motor and the airend at a fixed interval works well for a single plant compressor.
Reciprocating compressors are harder. NASA’s guide lists reciprocating machinery among the types “extremely difficult to monitor effectively” by vibration. Current, discharge temperature and run-load cycles give a more stable trend, with vibration as a secondary check at fixed points.
Hermetic and semi-hermetic refrigeration compressors seal the motor inside the compressor housing, in the refrigerant. A sensor on the shell can trend mechanical vibration, but the motor’s bearings and windings are out of reach. Current, run time, starts and the pressures and temperatures the refrigeration controls already measure become the condition signals.
Short-duty motors: dock doors, levelers and lifts
Some motors run for seconds at a time. A dock door motor, for example, might run 20 seconds per cycle and a few dozen cycles a shift. A vibration reading needs steady running, and there is little of it. Count cycles, record the peak and average current per cycle and track the time each cycle takes. NASA notes that “starting current in electric motors can routinely exceed five times full load running current,” and that a higher starting current and a longer starting surge can point to mechanical problems such as increased friction. On a door, a cycle that takes longer and draws more current often means a binding track or a failing spring.
The current signal you may already have
If you meter electricity by motor control center bucket, panel or machine, or read current from drives, you already hold a condition signal. It is not a signature, but it answers four maintenance questions without a new sensor.
- Is it running? Current above a set threshold for a set time means the motor runs. That gives run hours for usage-based maintenance and a running flag that tells you which vibration readings to keep.
- How hard is it working? In the linear region above half load, the DOE fact sheet’s current and voltage ratio gives an estimate of load. A rising trend at the same throughput is worth a look.
- How does it start? Peak current and the length of the starting surge, from a meter that captures them, point to friction and binding.
- How often does it start? Starts per hour reveal short cycling on pumps, compressors and fans, which wears contactors and windings.
The DOE O&M guide makes a similar point in its section on performance trending: much installed equipment already has useful instrumentation, and where it does not, installing “pressure, temperature, or current sensing data loggers can be relatively straight forward and rather inexpensive.” Our energy monitoring service uses the same meters for kWh per unit and demand peaks, so one installation can serve both energy and maintenance.
Know the limit, though. A panel meter read over Modbus TCP every few seconds gives RMS values, power and energy. It does not give the sampled waveform an MCSA spectrum needs. Signature analysis needs a separate capture: current probes or transformers on the motor leads, sampled fast enough and long enough for the frequencies you care about. Anything clamped or wired inside a motor control center or drive panel is installed by your electricians or a licensed contractor, under the plant’s electrical safety rules.
Example (fictional). A fictional distribution center meters each conveyor drive through its VFD. On one accumulation conveyor, the average running current at the same parcel rate climbs from 62% to 70% of nameplate over three weeks. Nothing has tripped. The maintenance planner adds the conveyor to that week’s inspection route: check belt tracking, roller bearings and the gearbox oil level, and take a vibration reading on the gearbox. The current trend did not diagnose anything. It decided where a technician’s hour went first.
Sensors, sampling and data: what to install and what to keep
The sensor, its mounting and the sample rate decide which faults you can see at all. The data plan decides whether the readings can be compared a year later.
Vibration sensors and mounting
NASA’s guide recommends “a low mass accelerometer (minimum of 100mV/g) with an attached rare earth super magnet” for most facilities machinery, and reports that a magnet-mounted accelerometer on a smooth surface gives “a usable upper frequency limit of 5 kHz.” Stud mounting and special sensors reach higher. A hand-held probe “severely limits the upper vibration frequency that can be accurately measured,” and repeatability falls when points are not marked and different people collect the data.
For permanent installation, NASA’s contract language puts monitoring points “on structural members.” It calls mounting on “bolted cover plates or other non-rigid members” unacceptable. Mount close to the bearings, in the directions that matter for the machine, and record each point’s location and orientation in the signal inventory.
Wireless and installed sensors
Battery-powered wireless sensors make installed vibration monitoring practical on assets where cabling would cost more than the sensor. They trade sampling for battery life, so read the datasheet for four things: the frequency range, whether the sensor sends spectra or waveforms or only overall values, how often it reports, and the battery life at that interval. A sensor that sends only an overall value and a temperature is a trend and alarm device. By NASA’s own rating of overall readings, that suits lower-criticality assets. Critical assets need a spectrum, from the installed sensor on demand or from a route.
Current signature capture
For MCSA, the sample rate must be more than twice the highest frequency you want to see, and the capture must be long enough for the resolution you need. As the slip example showed, a 10-second capture gives 0.1 Hz resolution. Such captures are large compared with RMS values but small in absolute terms.
Example (fictional). A 10-second capture at 10,000 samples per second on three phases is 300,000 samples. At 2 bytes per sample, that is about 600 kB. One capture per motor per shift, at a known load, is easy to store. Streaming the raw waveform from 40 motors around the clock is not. The usual design computes the spectrum at the edge, keeps the raw capture for a short period, and sends the spectrum, a few derived values and the operating context upstream.
Our data volume estimator does the same arithmetic for continuous signals: tags, sample interval and retention.
Context travels with every reading
Each condition reading needs the machine state, speed or drive frequency, load and product next to it, named the same way as the rest of the plant’s data. Without that, you cannot separate a worn bearing from a product change. The signal inventory worksheet has columns for unit, sample rate and source address. Add the operating band you will compare in. Getting drive and meter values to the gateway is the work described in machine connectivity.
Matching the signal to the asset’s criticality
How much you monitor should follow what a failure would cost, not which sensor is easiest to buy. The public guides agree on the shape of the answer, even if they do not give one rule.
- NASA’s guide makes run-to-failure “a conscious decision,” and names “non-critical electric motors less than 7.5 HP” among the items where reactive maintenance applies.
- The DOE O&M guide (2010) says MCSA “is typically limited to mission critical applications and/or those with life/health/safety implications.”
- NASA’s appendix recommends MCSA to “supplement vibration monitoring on critical motors.”
- PNNL’s page on prioritizing O&M actions lists the factors for choosing between preventive and predictive maintenance: “whether an effective test or inspection method exists, the cost of the test or inspection,” “the criticality of the system in question” and “how predictably the failure occurs.”
Turned into a starting rule for a small plant, with three criticality bands:
| Band | Typical asset | Vibration | Current |
|---|---|---|---|
| A, critical | Stops a line or the building, long repair, no backup | Spectrum, installed or on a fixed route | Trend from meter or drive; MCSA on large or hard-to-replace motors |
| B, important | Slows a line, or a backup exists | Overall value trend, spectrum when it moves | Trend from meter or drive |
| C, run to failure | No production effect, cheap and quick to replace | None | Run signal only, if a meter already covers it |
Adjust the rule by access and failure pattern. An inaccessible band B asset may still deserve an installed sensor, and a band A asset with a failure mode no signal detects needs a preventive task instead. The method for setting the bands is in our article on equipment criticality ranking. The interval questions belong to preventive maintenance frequency.
Alerts only help if they reach the person who schedules the work. Our maintenance software sends condition alerts into the CMMS you already use as work orders, through its API or a file exchange, rather than into a separate inbox.
A checklist for choosing signals on your motors
When we survey a line, we start from the motor and drive list, with read-only access to drives and meters, before anyone orders a sensor. The steps below follow the same order.
- List the motors. Asset, power, speed, driven machine, location, whether it has a drive, and whether a meter or drive already reports its current.
- Set the band. Use your criticality ranking. Band C motors stop here unless a meter already gives a free run signal.
- Mark access. Can a technician reach the bearings safely while the machine runs? If not, current or an installed sensor are the options.
- Name the failure modes you fear. Bearings, unbalance, misalignment and gears point to vibration. Rotor bars and air gap point to MCSA. Process load changes point to current trends.
- Check the drive. On drive-fed motors, plan signature measurements on the motor side, read drive output values for trends, and bin readings by speed.
- Pick the sensor and sampling. For vibration, check the frequency range and whether you get spectra. For MCSA, check the sample rate and capture length.
- Record a baseline. Take it under known load and speed, store it with the context, and repeat it after major repairs.
- Set alert and alarm rules. Start from 2-sigma and 3-sigma bands on your own data, add a time delay, and review them after every confirmed fault.
- Route the alert. Send it as a work request to the CMMS, with the reading, baseline, trend and operating context attached.
- Review after six months. Which alerts led to a finding, which were noise, and which failures arrived with no warning? Move signals and sensors accordingly.
If you want help with the first three steps on one line, including reading the drives and meters you already have, plan a pilot line with us.